GENERAL
Power Type: Diesel
Prime Power (kW/kVA): 58/73
Standby Power (kW/kVA): 64/80
STANDARD FEATURES
50°C rated radiator
Powder coated finish
External fuel tank connections
EVAC service points
110% bunded skid base
All moving parts are fitted with safety guards
Fitted sockets RCD protectors:
2 x 1Ph 15amp 3 pin
2 x 3Ph 32amp 5 pin
1 x 3Ph 63amp 5 pin
IP65 electrical boxes
IP66 electrical outlets
Rated lifting lugs
Emergency E stop
State of the art control system
Remote monitoring - Deep Sea
Door safety interlocks
ASSEMBLY
The engine and alternator are closed coupled by means of an SAE flange. A full torsional analysis has been carried out to guarantee no harmful vibration will occur. Antivibration pads are affixed between
engine alternator feet and base frame. Rubber diagonal isolators are specifically designed to reduce engine and alternator vibration and prevent distortion in the voltage and harmonic output of the generator. All iron and steel surfaces of the canopy fabrication have been sand blasted and then powder coated, which provides an excellent corrosion resistant surface.
CONTROL ASSEMBLY
The DSE6020 is an Auto Mains Failure Control Module suitable for a wide variety of single, diesel or gas, genset applications.
Monitoring speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level, the module will display warnings, shutdown and engine status information on the back-lit LCD screen and illuminated LED.
QUALITY STANDARDS
Our generator sets are compliant with all the main standards, such as ISO8528, ISO14000, GB755, BS5000, VDE0530, ISO3046, IEC34-1, AS3000.
WARRANTY POLICY
12 months, 1200 hours as per generator. Generators Australia Pty Ltd Warranty Policy.